消防演习
FIRE DRILL
fire-fighting squad
first-aid squad
technical squad
fireman
cut off concerned circuits, turn off ventilating blowers
close fire doors, windows, hatches, accesses, ventilators
control hydrant, fire hose, nozzle
carry portable extinguisher
separate inflammable from fire spot
administer international shore connection
carry first-aid box, perform first-aid
carry stretcher
administer the fixed CO2/foam fire-extinguishing system
automatic sprinkle system
the fixed pressure water-spraying fire-extinguishing system
control the emergency fire pump
close fire door, skylight,
shut off valves and cocks of oil suction pipes
呼吸器
BREATHING APPARATUS
composed of:
1. back plate with harness; The harness assembly is complete with shoulder pads and waist belt, fitted with special sliding buckles to ease adjustment. |
1. cylinder mounting kit shoulder strap hose retainer back plate waist strap buckle adjustable part clamp assembly |
2. cylinder periodic testing , refilling
|
cylinder rubber boot cylinder valve handwheel dust plug sealing tape handle section |
3. pressure reducer deliver a constant pressure of 5.5 bar irrespective of cylinder pressure. As cylinder pressure drops to 55+/-5 bar, a unique device actuates the audible warning
|
3. pressure regulator unit |
4. pressure gauge with high pressure hose
|
regulator hose high pressure hose breathing hose quick coupling connection |
5. face mask (with speech diaphragm) consists of: breathing valve visor frame assembly visor mask body locking strap neck strap with buckle head harness (speech diaphragm assembly)
|
black lever on breathing valve |
**** calculate the quantity of free air:
eg. one 3-litre cylinder charged to 30MPa (300 barf) contains 3*300=900 litres of free air.
average comsuption is 40 litre per minute.
**** don apparatus:
消防设备
firemans outfit
oxygen apparatus
portable foam applicater